1 3/4" Steel Post System--Economical Structural Support with Good Load Bearing Capacity
The Most ECONOMICAL System: ideal if load bearing capabilities are required now, or in the future.
Features Include...
-
1 3/4" THICK WALLS with expanded polystyrene core and vinyl covered hardboard both sides.
-
YOUR CHOICE OF COLORS AND FINISHES choose a standard IPO color, or customize your office color at no extra charge. (in most cases)
-
1/4" TEMPERED SAFTEY GLASS is standard in windows and doors.
-
NON-PROGRESSIVE DESIGN allows all panels, including door and window panels, to be removable without disturbing adjacent panels, roof decking or ceiling.
-
LOAD BEARING DESIGN where wiring posts serve as support columns for load bearing roofs and two-story units; and also act as electrical raceways.
-
STRUCTURAL STEEL POSTS are painted to match or coordinate with panel color.
-
NC CONSTRUCTION for Noise Control and Non-Combustibility is available.
-
COMPLETE ARCHITECTURAL SPECIFICATIONS are available on request.
Details and Specifications...
WALL PANELS: Panels will be 1-9/16" thick with 1/8" vinyl covered hardboard on both sides. Core material will be expanded polystyrene 1-5/16" thick. Panels are easily removable without disturbing adjacent panels, roof decking or acoustical ceiling, and are interchangeable with either door or window panels. Panel size will be 44-7/8" x 96" unless otherwise indicated on drawings.
WIRING POSTS: Wiring posts will be 16 ga. painted steel. All posts act as a wiring chase and have friction fit cover plates to allow easy access for electrical, telephone wires, computer cables, etc. Three piece wiring post allows entire system to be of Non-Progressive design. For load bearing roofs and two-story applications, the wiring posts act as support columns.
ELECTRICAL: Switch(es), duplex and air conditioner outlets will be provided in accordance with standard layout. Lighting fixtures will be 2' x 4' lay-in, troffer type, 160 watt with acrylic lens. A circuit breaker panel with breakers will be sized to meet the building's requirements. Note: wire, bulbs and runs for light fixtures in plenum above the ceiling are to be furnished by others. Low-voltage outlets for computers, telephones and intercoms are available.
ROOF DECK: Roof deck will be painted 22 ga. corrugated steel, 1-1/2" deep and cut to length for easy installation.
DOORS: Standard door will be 3070 x 1-3/4" steel, fully insulated (R-14), painted black, with sweep and prehung in a painted 18 ga. steel frame. Door frame will have 1-1/2 pair of hinges with key-in-knob lockset included.
ACOUSTICAL CEILING: Ceiling will be acoustical grid type, including white metal grid, hanger wire, and 2' x 4' white lay-in mineral fiber board ceiling tiles, 5/8"thick (UL Class 1).
BASE: Floor track will be formed 24 ga. steel. Finish base molding will be black vinyl, furnished in 12' lengths. Preformed outside corners are included.
GLASS: Glass will be 1/4" thick tempered safety glass premounted in an aluminum window frame. Windows will be located 43-1/2" from the floor and will be 37" in height by full panel width. The door light will be 1/4" tempered safety glass.
OPTIONAL NC PANEL CONTRUCTION
INPLANT 1-3/4" NC: Wall panels consist of 1/2" vinyl covered gypsum laminated to both sides of a 9/16" expanded polystyrene core.
|
|