The HEAVY-DUTY System: perfect for applications which require load bearing capabilities and additional thermal insulation.
Features Include:
-
3" THICK WALLS with expanded polystyrene core and vinyl covered hardboard both sides.
-
YOUR CHOICE OF COLORS AND FINISHES choose a standard IPO color, or customize your office color at no extra charge.
(in most cases)
-
1/4" TEMPERED SAFETY GLASS is standard in windows and doors
-
NON-PROGRESSIVE DESIGN allows all panels, including door and window panels, to be removable without disturbing adjacent panels, roof decking or ceiling.
-
LOAD BEARING DESIGN where wiring posts serve as support columns for load bearing roofs and two-story units; and also act as electrical raceways, with wiring access from both sides.
-
STRUCTURAL STEEL POSTS are painted to match or coordinate with panel color.
-
NC CONSTRUCTION for Noise Control and Non-Combustibility is available.
-
COMPLETE ARCHITECTURAL SPECIFICATIONS are available on request.
Request a Quote
Details and Specifications...
WALL PANELS: Panels will be 3" thick with 1/8" vinyl covered hardboard on both sides. Core material to be expanded polystyrene, 2-3/4" thick. Panels are easily removable without disturbing adjacent panels, roof decking or acoustical ceiling, and are interchangeable with either door or window panels. Panel size will be 44-7/8" x 96" unless otherwise indicated on drawings.
WIRING POSTS: Wiring posts will be 16 ga. painted steel. All posts act as a wiring chase on both sides, and have friction fit cover plates to allow easy access for electrical, telephone wires, computer cables, etc. Four piece wiring post allows entire system to be of Non-Progressive design. For load bearing roofs and two-story applications, the wiring posts act as support columns.
ELECTRICAL: Switch(es), duplex and air conditioner outlets will be provided in accordance with standard layout. Lighting fixtures will be 2' x 4' lay-in, troffer type, 160 watt with acrylic lens. A circuit breaker panel with breakers will be sized to meet the building's requirements. Note: wire, bulbs and runs for light fixtures in plenum above the ceiling are to be furnished by others. Low-voltage outlets for computers, telephones and intercoms are available.
ROOF DECK: Roof deck will be painted 22 ga. corrugated steel, 1-1/2" deep and cut to length for easy installation.
DOORS: Standard door will be 3070 x 1-3/4" steel, fully insulated (R-14), painted black, with sweep and pre-hung in a painted 18 ga. steel frame. Door frame will have 1-1/2 pair of hinges with key-in-knob lockset included.
ACOUSTICAL CEILING: Ceiling will be acoustical grid type, including white metal grid, hanger wire, and 2' x 4' white lay-in mineral fiber board ceiling tiles, 5/8"thick (UL Class 1).
BASE: Floor track will be formed 24 ga. steel. Finish base molding will be black vinyl, furnished in 12' lengths. Preformed outside corners are included.
GLASS: Glass will be 1/4" thick tempered safety glass pre-mounted in an aluminum window frame. Windows will be located 43-1/2" from the floor and will be 37" in height by full panel width. The door light will be 1/4" tempered safety glass.
OPTIONAL NC PANEL CONTRUCTION
INPLANT 3" NC: Wall panels include 1/2" vinyl covered gypsum laminated to both sides of a 2" expanded polystyrene core.
|
|