InPlant Prefab Buildings,
Modular Rooms & Partitions
THE MODULAR BUILDING ELEMENTS
Choose from InPlant’s supporting
metal BUILDING SYSTEMS, then
select the appropriate interior
WALL SYSTEM to suit your purpose.
PACKAGE OPTIONS
HEATING & AIR • A self-contained HVAC wall unit plugs into an adjacent dedicated outlet in most Modular Room buildouts. For larger Prefab Buildings, we can quickly fabricate additional plenum space for central air ductwork.
FLOORING • InPlant’s Two Story Modular Complex is supplied with vinyl tile as the standard finished flooring for the upper level. Carpet or other flooring may be used. Lower-story flooring is not an integral part of the Modular Offices. Flooring options are available and are set after building installation.
STAIRS & RAILINGS • Accessories such as Prefabricated Stair Systems, Ladders, Handrails, and Gates are available. Engineered drawings and specifications will be supplied for approval.
ELECTRICAL • Electrical components are mounted in the prefab buildings during installation. Standard circuit breaker panels consist of 125A panels with 70A main breakers and may be upgraded as needed. Single pole and 3-way switches, as well as duplex and other outlets, are provided in a standard layout. Individual breakers and the number of breakers are sized depending on the electrical needs of the building. Electrical wiring, conduit, communication cables, and light bulbs are to be provided by an electrician or technician on site.
InPlant offers a modular wiring option that snaps together, linking all the pre-wired lights and outlets to the junction box near the load center.
InPlant structural Building Systems are designed with metals appropriate for environment and capacity requirements – using either 20 or 16-gauge painted steel or satin anodized aluminum extrusions.
The MODULAR BUILDINGS SYSTEM consists of Wiring Studs, Corner Posts, Wall Starters (on Partitions), Ceiling Cap, and Floor Track with Vinyl Base Molding.
Load-bearing Wall Support & Wiring Studs • The supporting Wiring Studs are located at each Wall Panel junction – every 4 feet or less. See InPlant Building System options and the different features of the lightweight and load-bearing wall options. In addition to structural support, the Wiring Studs act as wiring raceways with removable cover plates, which allow easy access to electrical conduit and communications cables.
Corner Posts • InPlant Corner Posts incorporate the expandable and non-progressive features of the InPlant Prefab Rooms and Modular Building System. The Corner Posts of extruded aluminum are anodized or painted to match your Wall Panel selection or custom paint color.
Wall Starters • For single Wall Partitions (room divider wall system) and 2 or 3 wall configurations, InPlant Wall Starters are anchored in existing walls and securely set the leading Wall Panel.
Ceiling Cap & Trim • The Ceiling Cap with a metal angle is seen on the exterior, as it conceals the roof deck (20ga steel or aluminum option).
Floor Track & Base • The Floor Track anchors to the existing floor (24 gauge steel or aluminum option). Vinyl Base Molding conceals the Floor Track along the interior and exterior of the Prefab Rooms and extends around the outside corners.
NOISE CONTROL & SAFETY WALL PANELS • InPlant offers a variety of non-combustible and insulated Wall Panels engineered to meet national building codes and OSHA safety requirements.
Choose the appropriate WALL PANELS for your Modular Room in either 1¾˝ or 3˝ thickness and standard 8´ to 26´ height, which can extend taller. See Wall Panel selections.
Door Options • InPlant single or double steel swing doors are pre-hung and made of steel shell with an insulated core (Standard 36˝x 7´ includes hinges, sweep, and key-in-knob locket. Lever locks and panic exit hardware available). Custom sizes are available, as well as high-speed or manual roll-up doors, bump doors, and sliding or strip doors. InPlant designs of Modular Room and Partition Systems allow for many types of doors and frame openings that can accommodate conveyors, turn-tables, and many other loading and unloading components.
Fixed or Functional Windows • InPlant window units are made of ¼˝ thick tempered glass pre-installed in anodized aluminum frames and span the entire panel width. Often, glass height is extended in Office Partitions (room divider wall system) and inside plant Mezzanine Offices for aesthetics or viewing purposes (standard size 41˝ high). Alternate window materials are available, such as tinted, wire glass, laminated, insulated, acrylic, polycarbonate, and safety glazing for welding and Laser Enclosures. For functionality, you may choose sliding windows.
LOAD-BEARING WIDE SPANS & ROOF STORAGE • InPlant’s Modular Prefab Buildings are known for their strength and wide spans up to 40´ without center support columns in non-load-bearing applications. Or, you may gain rooftop storage or production space with the load-bearing systems reinforced with recessed I-beams on 48˝ centers, giving a load capacity of up to 125 lb per square foot.
Decking Options • Prefab Buildings are covered with a robust corrugated steel Roof Decking (22ga B-deck) and then covered with various overlay materials, including OSB, plywood, tread plate, and other optional materials.
Acoustic Ceiling & Lighting Fixtures • Steel decking provides strength to support the 2×4 grid ceiling with recessed lighting at various heights. The standard lighting fixtures have an acrylic lens cover. Specialized lighting may easily be incorporated into your InPlant Modular Buildings.